By: Gregory R. Stockton
President of Stockton Infrared Thermographic Services, Inc.
FORWARDInfrared thermography has become a very popular means of testing electrical and mechanical systems over the past fifteen years. As it relates to predictive/preventive maintenance (P/PM), infrared thermographers look at the thermal energy that is emitted from an object or group of objects, explain what is normal, see abnormalities and report them. In turn, someone can act to fix whatever is wrong as long as they get the information in a usable, graphic and easy-to-understand fashion. This method works well on heat emissions from most objects, including building roofs. A well-prepared, graphic and accurate map of the infrared signatures of a roof can be of significant benefit to the roof consultant at all stages of that roofs service life. This type of testing is commonly referred to as an infrared roof moisture survey. Infrared thermography is not leak management, it is predictive maintenance. No matter how the water got into the substrate, the purpose of this type of survey is simply to find and document where the water is. Performing infrared roof moisture surveys while standing on the roof is not the best method because imagery from a walk-on survey is not as useful as aerial imagery.
THE SCHOOL OF FROZEN TOES
These revelations did not discourage us from performing roof moisture surveys. We knew that it worked well on most roofs. We just had to figure out a better way to perform the inspections. In the case of roofs, infrared thermographers should see their role as providers of excellent infrared imagery, nothing more, nothing less: the mappers of heat. We do not profess to know everything about roofs or how to fix them. Our role is to obtain and provide quality information that will help experts at roof construction, installation and repair.
ONCE UPON A ROOF
When we started conducting walk-on infrared inspections of roofs, we had no idea what nightmares these surveys could be. First, nighttime conditions have to be right. Having low winds, clear skies and some sunshine during the preceding daylight hours is usually not too much of a problem. However, mobilizing a certified infrared thermographer, a helper, a building owners representative, and a roof consultant to meet at a site on a specific scheduled date when the weather is just right, takes much more flexibility and some luck. Also, some roofs do not exhibit a good infrared signal, primarily for two reasons. 1) The surface is too reflective, and 2) the roofs ballast is so thick (or dense), that daylight radiation is not absorbed into the substrate (insulation), therefore it cannot be emitted back into the atmosphere at night. There are other reasons why infrared thermography is of little value on certain other roof types.
Suppose we have a roof that lends itself to infrared (other than metal, most roofs do). We have scheduled the job, everyone is in attendance and the weather is favorable. The biggest problems then become logistical in nature.
Again, the infrared thermographers job is to make a graphic, accurate, and easy-to-understand report. For legitimate results, you need excellent imagery. To get excellent imagery, a high angle of view and high resolution are needed. When one is standing on the roof, eye-level is at best six feet over the surface. If you are looking out over a roof with large areas of moisture contamination (even if you have a good infrared camera), there is virtually no way, without taking multiple shots, that you can get a 900-square foot amoeba-shaped blob, or an 80-foot long striation of subsurface moisture resolved on the screen in one infrared shot. If you take multiple shots, the report starts to become confusing, and the visual images that you have to take the next day are going to be hard to reconcile with the infrared images. J.P. "Sonny" Ledoux, an infrared thermographer with over twenty years experience describes the problem best saying, "When performing walk-on roof surveys, many times you cant see the forest for the trees". Marking the roof is not difficult, if you are able to yell out the commands well and your helper with the marking paint is adept at his task. Then there are the drawings. Many times I was faxed a photocopied fire plan of the building, without any rooftop equipment indicated, for use as my roof drawing. We really struggled with the drawings, especially on the night of the survey.
Considering the costs, scheduling woes, logistical problems and danger (from tripping, poking yourself in the eye, falling off the roof or dropping $80,000 worth of your livelihood), together with how much trouble the report is going to be to produce, and its no wonder that infrared thermographers survey comparatively few roofs It is a lot easier to make a living checking electrical switchgear!
IMAGERY VS. PAINT
Some of you may be thinking at this moment that:
No matter which method or style that you currently use to perform these surveys, the end product will benefit from high quality imagery and drawings. The end product is not only a printed document, but also the knowledge of where the moisture is in the roof, so that precise, cost-effective repairs can be accomplished.
As stated earlier, excellent imagery demands a high angle of view and high resolution. In order to get excellent infrared and visual imagery of that 900-square foot blob onto a printed page, a lot of costly work has to be done with an infrared and visual camera on the roof, and then with a computer in the office to create the report. To avoid reflections and to image a large area at once, we used to climb rickety ladders with very expensive infrared cameras so we could get as high above and as close as possible, to a 90-degree angle over a particular area. This was done by looking down from a higher roof to a lower one, or climbing on air washes and other rooftop equipment. All this takes time and can be dangerous. Some roofs have only package air conditioning units, allowing for maybe 12 feet over the surface at best. So, we decided to try a helicopter.
WHY AERIAL INFRARED
The breakthrough came in the form of the 5122 focal plane staring array chip. These cameras can be used for aerial infrared because they have 512x512 pixels a total of 262,144 pixels, which is four times the resolution of the 2562. Thats four times farther away at the same resolution. Because of the high-resolution, this type of camera can be mounted in a fixed-wing aircraft allowing the infrared thermographer to quickly fly over buildings, obtaining great imagery of large areas of roofs. What used to take a four-man crew six hours can be done better and less expensively, in 60 seconds.
Fixed-wing aerial infrared imaging provides:
More advantages:
FLEXIBLE REPORTING
Unedited videotape. If scheduled in an area where the plane will be operating on a particular night, a building roof can be imaged (recorded on digital videotape and VHS) and the unedited VHS videotape can be delivered to a local airport that night. The owners roof consultant can review the videotape the next morning.
Edited videotape. An edited videotape can be made from the original digital videotape and copied onto VHS.
Printed thermographs. Printed infrared thermographs (infrared pictures) of each roof section can be captured and printed in high-resolution.
Aerial photographs. Printed photographs of the roof (straight down) and building site photographs (lower angle beauty shots of the building and property) can be developed and printed. Photographs, of course, must be taken during daylight hours, requiring a second flight over the building. The costs increase, but a straight down photograph of a roof section aids significantly in the infrared analysis, showing stains, equipment and roof boundaries.
AutoCAD drawings. AutoCAD drawings, printed and saved to disk, can be made by analyzing all the infrared, photographic and drawing information. Often, the roofs old drawings are outdated and inaccurate. The old drawings can be corrected by using the new photographs as a reference.
Digital and printed report. A complete quantitative infrared roof moisture survey report would include all of the above, printed in high resolution and saved to a CD, put on the Internet with a password to access, and/or e-mailed to all the interested parties.
A roof consultant must verify all infrared data and analyses. The infrared report should be reviewed and the printed data taken on the roof to aid in visual, destructive and non-destructive testing. I cannot overstress this point! Infrared images of the roof, no matter how spectacular, are only signatures of heat. As stated earlier, there are many causes of heat (or apparent heat) on a roof. Professional verification is a required part of the survey, without which the information is not and should not be considered reliable. I believe this is one of the reasons that this type of infrared survey is not performed more frequently.
OTHER CONSIDERATIONS
- The prospective owner of a building could have the roof flown over before he buys it. If the roof looks good, he would not have spent much money to find out. If it looks bad, he can ask for a more detailed analysis, and use this information as a bargaining chip to negotiate the price of the building.
- After a new installation, every roof that can be imaged effectively should have a survey performed to verify that no wet insulation boards were laid down during construction. Also, aerial infrared images taken soon after installation, become very important documentation later as the roof ages, since it can be used for comparison. Subsurface fasteners are also evident (in the infrared) on certain roof systems.
- Designers could have a roof flown over in order to furnish a quantitative document to all bidders, in the form of verified AutoCAD drawings, for the surgical removal and replacement of all wet insulation.
- Aerial roof infrared has a big advantage over walk-on roof infrared in the ability to trend areas of a certain roof or roof system. A one-year-old aerial thermograph can easily be superimposed over a new aerial thermograph, producing a three-part composite: the area of moisture one year ago, the area of moisture now, and the difference (growth). Using this information, the rate of growth for that particular roof system can be reasonably extrapolated.
- Permission to fly over any building in the US is not required. The airspace over a few sensitive federal buildings may be restricted, but even in this rare case, permission is usually granted to fly over.
- Soon, the insurance industry will discover the potential of aerial infrared thermography on their insureds building roofs. Highly insured facilities in an area can be surveyed from the air in a matter of minutes, especially when the insurance company has a high concentration of insured buildings in a particular area. If problems are discovered, the insured can be informed that a more effective roof maintenance program needs to be started at that facility or, for instance, their rate and/or deductible will be increased, or coverage discontinued. Also, if a particular area is prone to hurricanes, tornadoes, or severe storms, the insured roofs in that area can be flown over on an annual basis, thereby limiting the insurance companies liability, in case of roof damage, to the pre-storm condition, as compared to post-storm. Aerial infrared and visual imaging can also be used to quickly assess roof damage after a disaster, when security and/or automobile road conditions make on-roof surveys impossible, for the purpose of determining which roofs should receive top priority.
CONCLUSIONSOnce a roof consultant has determined that a particular type of flat or low-slope insulated roof lends itself well to infrared inspection, it should be considered an integral part of the roof asset management program. Regular infrared surveys will help the roof consultant to assess the roofs condition at all stages of its service life. Whether performed on-roof or aerial, infrared imaging only provides a picture of the heat. Infrared analyses must be professionally verified on the roof, in order to be reliable. Infrared heat signatures are most efficiently and effectively gathered from the air. In order to get a graphic, usable report, the infrared thermographer must obtain high-resolution infrared images of large areas from high above. Therefore, the infrared camera used must have a detector with enough pixels to achieve the desired resolution from the maximum desired altitude